Model
|
POW-Keeper1220
|
POW-Keeper1230
|
POW-Keeper1240
|
Rated charge current
|
20A
|
30A
|
40A
|
System rated voltage
|
12V/24V Auto work
|
Voltage range of battery
|
8-32V
|
Max open voltage of PV module
|
55V
|
75V
|
100V
|
Battery type
|
User default, Sealed, Flooded, GEL, LiFePO4
|
Equalized charging voltage
|
Maintenance-fee lead acid battery 14.6V, GEL: No: Lead acid flooded battery: 14.8V
|
Absorption charging voltage
|
Maintenance-fee lead acid battery 14.4V,GEL: 14.2; Lead acid flooded battery: 14.6V
|
Floating charging voltage
|
Maintenance-fee lead acid battery,GEL, Lead acid flooded battery: 13.8V
|
Low voltage re-connection (LVR)
|
Maintenance-fee lead acid battery,GEL, Lead acid flooded battery: 12.6V
|
Low voltage disconnection (LVD)
|
Maintenance-fee lead acid battery,GEL, Lead acid flooded battery: 10.8V
|
Static loss
|
<9.2mA 12V; <11.7mA 24V
|
High voltage disconnection (HVD)
|
16V (24V x 2)
|
Duration of absorption charging
|
2 Hours
|
Light control voltage
|
5V
|
Charge loop voltage drop
|
<0.29V
|
LCD Temperature
|
-20°C~+70°C
|
Operating Temperature
|
-20°C-+55°C (To run at full rated current continuously)
|
Operating Temperature
|
-20°C-+55°C (To run at full rated current continuously)
|
Working humidity
|
<95% No condensation
|
Protection class
|
IP30
|
Dimension (LxWxH) mm
|
123x178x48
|
135x202x55
|
150x220x67
|